ConnectWise said on 16 November that screenconnect exploitation targeting partner environments was continuing, as Huntress reported SCKit malware deployments and attacks on unpatched managed service provider technician systems.

The activity matters because MSP technicians can administer multiple customer networks from one workstation. Huntress said those machines commonly hold remote monitoring and management consoles, saved credentials and access to every customer, making a compromised technician client a route into many downstream environments.

ConnectWise said it had completed its investigation into unauthorised access affecting partner ScreenConnect environments. It recommended that customers ensure the technician client runs version 26.6.5 or later, according to The Hacker News. The company also said additional activity against on-premises environments continued where identified third-party extensions remained enabled.

How SCKit reached managed endpoints

Huntress said it began a rapid response on 11 November after observing worm-like activity. An attacker issued Run commands through cloud-hosted panels, placing unauthorised ScreenConnect clients and relays for session cookies on hundreds of managed endpoints.

The security company called the malware SCKit. It said the malware appeared to abuse a third-party extension with a vulnerability in the ScreenConnect server component, rather than directly exploiting CVE-2026-84869. Huntress said the activity attempted to prepare vulnerable systems to intercept later connections made by technicians through a relay.

Huntress distinguished that activity from a separate campaign it reported on 13 November. That campaign planted unauthorised guest sessions disguised with cryptocurrency exchange names across over 100 ScreenConnect servers operated by MSPs. Researchers did not observe those sessions being used to run malicious files, but said the names could lure a technician into opening a session.

What the ScreenConnect exploitation flaw allows

ConnectWise disclosed CVE-2026-84869 on 8 September 2026 and assigned it a CVSS score of 9.9, according to Huntress. The US Cybersecurity and Infrastructure Security Agency added the vulnerability to its Known Exploited Vulnerabilities catalogue on 11 September.

ConnectWise's advisory said a guest in Support and Access sessions could initiate file transfers that the host client on a technician's computer accepted and acted on without authorisation or confirmation. Those actions included running the file with elevated rights. The vendor identified 26.6.5 as the release containing the fix for host clients and Access agents. As a temporary measure, it advised customers to remove the TransferFiles permission.

Huntress said a malicious guest exploiting the flaw could push a file to a technician's computer and make that technician's own client run it. No prompt would appear to the technician. The technician would only need to join a session controlled by an attacker, or a genuine customer support session that an attacker had entered as an additional guest.

On 12 November, Huntress observed a technician at one MSP joining a blank-named Access session. Process telemetry showed the host client running a guest-pushed batch file, which then relaunched itself hidden through PowerShell and WScript.Shell, according to the company's report.

The script decoded a Base64 Telegram bot token and chat ID, reported the new victim and checked the Windows version and administrative rights. It then downloaded an MSI package and unpacked it as an administrative image, which Huntress said left no install record.

The final executable was named WindowsUpdate.WindowsClient.exe. Huntress identified it as a ScreenConnect client with altered branding that communicated with a relay controlled by the attacker, giving the attacker remote access that resembled legitimate software.

Updating the server alone does not fix the client vulnerability because the vulnerable code runs on the technician's machine.

Hundreds of thousands of file-run requests

Huntress said attacker guests made 688,000 run-file requests across 42 MSP ScreenConnect servers between 20 October and 16 November. The requests sought files named update.bat or update_ followed by an identifier and .bat, and originated from 29 IP addresses.

Ten guest sessions originating from seven IP addresses generated 70,414 requests over three weeks on the server with the highest volume. Huntress said the repeated requests increased the chance that a file would be waiting when a technician joined.

The exact batch file later observed on the compromised technician workstation was sprayed at five MSP ScreenConnect servers on 12 November. The five servers received it within two seconds of one another at 16:03 UTC, 43 minutes before the compromise, according to Huntress. Each server received between 585 and 5,671 requests, and three were still receiving them on 16 November.

Huntress said it assessed with high confidence that the spray operator and the operator of the domain used by the downloaded payload were the same. It also found 27 spray sessions across 17 servers with the session Company property set to crypto client.

Canary files and Startup-folder attempts

On 13 November, another MSP's technician connected to a session that appeared to represent a laptop. Two seconds later, the guest pushed a file called marker.txt, and the technician's client opened it in Notepad++ about three seconds after that, Huntress said.

Nothing else followed before the host went offline 18 minutes later. Huntress described the harmless file as a classic canary: a test that proves an exploit works against a target before a damaging payload is sent.

The most targeted activity Huntress found occurred in October. Across three genuine customer support sessions, an attacker joined as an additional guest and requested a path traversal into the technician's Windows Startup folder. If honoured, the path would have placed a script there to run at the technician's next logon.

Those pushes occurred on 23, 24 and 27 October while different technicians were connected. Two technicians used vulnerable Windows clients, while the third used a Mac client, where the Windows Startup path failed, according to Huntress.

What ConnectWise and Huntress recommend

Huntress said every technician's ScreenConnect host client should be updated to 26.6.5 or later, alongside any Access agents listed by ConnectWise. It said administrators can consult the connection history on the server to see the client version used by each technician, allowing them to identify outdated clients.

ConnectWise's interim mitigation was to remove the TransferFiles permission. Its latest guidance also called for technician clients to run 26.6.5 or later, while warning that activity continued against on-premises systems with the identified third-party extensions enabled.

The immediate priority for MSPs is therefore to check technician client versions, apply the vendor's listed fixes and review exposure across remote-access sessions. Organisations building a wider maintenance process can also follow DailyTech.press guidance on keeping software and devices updated and turning on two-factor authentication.