On 13 November 2026, Rapid7 identified an attack exploiting confluence cve-2026-90436 in one customer's Atlassian Confluence Data Center deployment. The security company called for exposed systems to be fixed urgently, ahead of routine maintenance schedules.
The flaw matters because it allows unauthenticated remote code execution through Apache Axis 1.x, a component used by some Confluence versions. Rapid7's observations show how a single exposed collaboration server can provide access to stored credentials, internal systems and cloud services.
The Apache Software Foundation disclosed CVE-2026-90436 on 6 November 2026. It is a critical unsafe reflection vulnerability, classified as CWE-470, in Axis 1.x. The US Cybersecurity and Infrastructure Security Agency assigned it a Common Vulnerability Scoring System score of 9.8 Critical, according to Rapid7.
Apache Axis is a Simple Object Access Protocol implementation used to create Java web services. Rapid7 said on 16 November that some versions of Confluence Data Center and N-able N-central use the affected library. Both products require a non-default configuration to be vulnerable.
Which Confluence versions are affected
Atlassian lists Confluence Data Center versions 1.x through 9.x as affected when the Remote API (XML-RPC & SOAP) setting is enabled, according to Rapid7's report. Version 9.2.28 is the fixed release.
The setting has been disabled by default for new installations since Confluence 3.0. That limits the affected population, but it does not remove the risk for older installations or systems where administrators enabled the interface for integrations.
Confluence 10.x and later removed the feature and are not vulnerable. Atlassian Cloud is also unaffected. These distinctions are important: administrators should establish the product version, deployment model and configuration before assessing exposure.
Axis 1.x through 1.4 is affected and has reached end of life. Apache does not plan to publish a fixed Axis 1.x release. It recommends moving to another SOAP engine, such as Apache Axis 2, or using an Axis 1.x build with its patch applied. Organisations using affected products should follow the product vendor's remediation instructions.
How to fix and mitigate Confluence CVE-2026-90436
Rapid7 recommends upgrading affected Confluence installations to version 9.2.28 or a current unaffected 10.x release. It says internet-accessible instances with the relevant APIs enabled should be prioritised, while internal deployments should also be checked.
For organisations unable to install the update straight away, Rapid7 describes a configuration workaround. An administrator should go to General Configuration, then Further Configuration, and edit the settings so that Remote API (XML-RPC & SOAP) is no longer selected before saving. Rapid7 said the change takes effect without restarting Confluence.
That workaround can disrupt integrations that use the API. Administrators therefore need to identify dependent services rather than treating the configuration change as consequence-free. Atlassian's advisory remains the reference for current fixes and mitigation instructions.
The advice is consistent with the wider need to keep internet-facing software maintained. DailyTech.press has separate guidance on how to keep software and devices updated, but this vulnerability warrants an emergency response rather than waiting for a routine maintenance window.
What Rapid7 observed during the intrusion
Rapid7's managed detection and response team responded on 13 November to a surge of alerts about abnormal child processes launched by a Confluence server. When analysts examined the access logs, they found POST requests sent without authentication to `/plugins/servlet/soap-axis1/confluenceservice-v2`. The server answered each one with an HTTP 500 Internal Server Error.
The error responses did not mean the attempts were harmless. According to Rapid7, device monitoring recorded Bash and curl being started by the Java process behind Confluence, running under the service account reserved for Confluence. This activity followed the requests within seconds.
The intruder subsequently executed shell commands and scripts in their hundreds, encoding them in hexadecimal and retrieving them through short-lived Pinggy and Cloudflare Tunnel addresses. Commands wrapped output in labelled delimiters and carried sequential task identifiers. Rapid7 said that structure suggests AI-assisted automated tooling, and described the scripts as likely AI-generated; those are assessments, not confirmation of who conducted the intrusion.
Once inside, the intruder began mapping the compromised machine and its network, while examining how Confluence was configured and looking at its encryption keys and database settings. Rapid7 said that little more than three minutes elapsed between the first execution it saw and the intruder logging into MySQL using the database credentials belonging to Confluence itself.
Queries covered page bodies, application links and attachments whose filenames pointed towards credentials, tokens, virtual private network configurations and private keys. Scripts also went through the directory where Confluence stores uploaded page attachments by default, at `/var/atlassian/application-data/confluence/attachments/v4/`. They read Office files, looked for login details and searched for payment card numbers. Rapid7 said Luhn checks were used to filter false positives.
The activity extended beyond the Confluence host. A credential belonging to a Confluence application was used to ask the organisation's internal Atlassian Crowd API for account and group information. The intruder then directed Impacket's GetNPUsers.py at a domain controller in an attempted AS-REP roasting attack. Rapid7 said those attempts failed.
Nevertheless, the observed access relied on credentials stored in Confluence. About four hours after exploitation began, the intruder had obtained credentials for a service account and started running queries against a cloud data warehouse used in production. Around 12 hours after the initial exploit request, a Microsoft 365 sign-in followed under an integration service account, using legacy authentication from 192.238.253[.]176, Rapid7 said. The same address appeared in a Pinggy tunnel hostname and earlier exploit requests.
Compromise indicators defenders should check
Rapid7's report provides a practical sequence for compromise assessment. Start with Confluence access logs for unauthenticated POST requests to the SOAP servlet path. Investigate requests returning HTTP 500 rather than dismissing them as failed attacks.
Next, examine endpoint telemetry for the Confluence Java process spawning Bash, curl or other unexpected child processes. Check whether those processes ran under the dedicated confluence service account and whether activity followed requests within seconds.
- Review logs for the observed SOAP requests and HTTP 500 responses.
- Look for hex-encoded commands, labelled output delimiters and sequential task identifiers.
- Check connections to temporary Pinggy or Cloudflare Tunnel domains.
- Investigate unexpected MySQL authentication using Confluence database credentials.
- Review searches or access involving credentials, tokens, VPN configurations, private keys and attachments.
- Examine Crowd API queries, domain-controller activity, cloud data warehouse access and Microsoft 365 legacy authentication.
Rapid7 lists IP addresses and domains associated with the observed Confluence exploitation in its report. N-able's 13 November incident update separately lists IP addresses and associated URLs for N-central compromise assessment. Defenders should consult those original lists rather than rely on a partial reproduction.
The presence of these indicators should prompt investigation, but their absence does not establish that an environment was unaffected. That caveat is central to proportionate triage: a clean indicator search is not proof of safety.
What this means for defenders
Rapid7 has documented active exploitation, but the material describes detection in a customer environment and does not establish the campaign's overall scale. It would therefore be wrong to infer how many organisations have been compromised from this report alone.
The operational lesson is narrower and better supported. An exposed Confluence instance contained credentials and documents that enabled rapid movement into other systems. Defenders should combine patching with log review, endpoint investigation and scrutiny of credentials stored in or accessible through Confluence.
The case also echoes recent reporting on ScreenConnect attacks against unpatched systems, where exposed remote-access software created opportunities for intruders. The products and flaws differ, but both reports place prompt remediation and compromise assessment at the centre of the response.
N-able reported separate exploitation against N-central on 13 November for a vulnerability that Rapid7 said strongly correlates to CVE-2026-90436. A proof-of-concept exploit targeting N-central was published on 12 November as part of public zero-day disclosures. On 16 November, N-able released N-central 2026.4 HF3, version 2026.4.1.39, which disables the Legacy API feature that exposed the vulnerable Axis attack surface. Rapid7 recommends that N-central users upgrade on an emergency basis and follow the vendor's advisory for the remaining responsibilities.
For Confluence administrators, the next steps are clear from the available guidance: identify affected versions and configurations, upgrade or disable the Remote API, and investigate exposed systems. They should also monitor Atlassian's advisory and Rapid7's report for updated fixes and indicators.